WC-1 Type C is a cork-filled mastic with low thermal conductivity and good moisture resistance. WC-1 Type C is used to retard condensation on the surface of piping, tanks, or other equipment which operates at a temperature below the dew point of the ambient air. It is designed for use on systems involving moderate temperatures such as cold water lines, but will not be effective on extremely cold surfaces. Normal applications range from ¼” to ½” total dry thickness.

WC-1 Type C is suitable for application by trowel or spray. Surfaces to which WC-1 Type C is to be applied MUST be clean from oil or other contaminants. Carbon steel must be primed with a primer approved by Vimasco prior to application of WC-1 Type C.

After proper application and complete curing on an appropriate type of system, WC-1 Type C, provides not only condensation control, but also some additional corrosion protection and sound deadening properties. It dries to a heavily textured appearance with the cork showing through the surface of the coating.

It is recommended that up to 4 applications of WC-1 Type C be used to obtain the specified dried thickness (depending on the desired thickness and the application conditions). Each coat should be allowed approximately 24 hours drying time (depending upon ambient conditions) before applying more material over it.

WC-1 Type C is a water-based product so it poses no health or flammability hazards on the job site. WC-1 Type C should not be applied where it will be exposed to continual standing or running water as this will eventually soften and degrade the coating.

Product Information Data

COLOR

E2 Gray, Black (Special colors available upon request)

WET FLAMMABILITY INFORMATION

No flash to boiling (212ºF) closed cup (ASTM D 93)

COVERAGE (ASTM C 461)

4.7 sq. ft/gal at 1/4” dry thickness (.11 m²/liter) at (6.35 mm)

CLEANUP

Wet state – water
Dry state – safety solvent

DRYING TIME (ASTM D 1640-69)

To touch: 2 hours

Must have minimum of 24 hours drying time between applications.

RECOMMENDED SHELF LIFE

18 months in unopened container at 40°F (4°C) to 90°F (32°C)

WEIGHT PER U.S. GALLON (ASTM D 1475)

THERMAL CONDUCTIVITY (ASTM C 518 70)

50˚F (10˚C) .63 btu in hˉ¹ ft.ˉ² deg. Fˉ¹
73˚F (23˚C) .64 btu in hˉ¹ ft.ˉ² deg. Fˉ¹

SOLIDS

59% by weight
73% ± 2% by volume

VOC (Volatile Organic content, less water) (ASTM D 3960)

40gm/L, meets requirements for LEED IEQ 4.2 low emitting material

APPLICATION TEMPERATURE RANGE

40°F (4°C) to 120°F (49°C)

 

CAUTION

The addition of water or any thinning agent to this product will change its physical properties and will adversely affect its performance. No expressed or implied warranty will be offered on applications where this product has been thinned or altered in any manner.

WC-1 Type C must be protected, during and after application, from precipitation, freezing, oil, grease and foot traffic UNTIL IT IS THOROUGHLY CURED. It must be protected from freezing at all times prior to application during storage and shipment.

SERVICE TEMPERATURE RANGE

0ºF to 180ºF constant (-17.8ºC to 82.2ºC when cured)